Customized Sintered Filters

English
Leave Your Message

China Suppliers Medical Oxygen Concentrator Filters - Enhance Purification and Extend Equipment Life

This product is essential for medical and home oxygen therapy as well as overall health care. It serves as an effective filtration and purification system for the exhaust air inlet of oxygen generators. By significantly reducing exhaust noise, it ensures compliance with the necessary flow rates in various oxygen environments. This promotes stable oxygen concentration, prolongs the lifespan of the oxygen generator, and safeguards the well-being of users. As a leading China supplier and factory, we are committed to providing high-quality solutions that enhance the performance of oxygen therapy equipment.

    Message

    AI Helps Write
    Send

    Main Features

    ● Meet the flow and flow rate requirements of medical and home oxygen generators when passing through the muffler with outstanding sound and noise reduction effect.

    ● The raw material is made of medical grade ultra-high molecular weight polyethylene.

    ● Size and structure can be adjusted and customized according to the customer's requirements.

    Oxygen Concentrator Filters Parameter

    The following is a comprehensive introduction to Oxygen Concentrator Cartridge, covering product definition, core parameters, production process, technical advantages and application areas, combined with industry-specific information:

    Parameter Specification Description
    Filtration precision 0.3-5μm (medical grade), 1-30μm (industrial grade) Highly efficient interception of small particles, higher precision for medical grade
    Material Ultra-high molecular weight polyethylene (medical grade), polyester fiber + wood pulp fiber (industrial grade), film-coated polyester nonwoven Medical grade materials need to be biocompatible; industrial grade focuses on corrosion resistance
    Size Dimensions Diameter: 320-360mm; Length: 660-2000mm (industrial), Small household: 56×21mm (can be customized) Industrial cartridge is large in size to adapt to high airflow; household size is flexible
    Temperature/Pressure Resistance Operating Temperature: ≤150℃; Pressure Resistance: ≥50kPa (water-closed) Adaptation High-temperature environment, self-sealing in case of water to prevent liquid backflow
    Flow rate adaptability 0.5-60m³/h (industrial); 1-5L/min (household) Match with different power requirements of oxygen generator
    Lifespan about 2200 hours (industrial); 3-6 months (household needs regular cleaning) Need to be replaced in advance when the industrial environment is harsh

    Oxygen Concentrator Filters Production Process

    Oxygen concentrator cartridge production is divided into two stages: "Filter material processing" and "Cartridge assembly":

    Stage 1
    Filter Material Pre-Treatment

    Raw material inspection: the filter paper is inspected by light, and the pinholes and breaks are repaired (coated with latex).
    Folding: The filter paper is folded according to the template, and the excess is cut to make sure that the pleats are evenly spaced to increase the filtration area.

    Stage 2
    Filter Cartridge Assembly

    Gluing and fixing: the paper core is positioned by conveyor belt, and the mechanical arm is double-sided gluing (polyurethane adhesive), bonding the end cap and the protective net.
    Edge trimming: cut the edges and install the sealing ring (closed-cell rubber) to ensure air tightness.
    Performance test: test filtration efficiency, resistance and sealing, package after passing.

    Key Technology

    Industrial filter element adopts "wide pleat folding technology" to enhance the dust capacity; medical filter element needs aseptic environment production.

    Oxygen Filter Advantage

    High-efficiency purification

    HEPA grade filtration (medical) or coated polyester (industrial), interception rate of PM2.5, bacteria ≥ 99.9%.

    Noise reduction design

    Special pore structure reduces airflow noise (household oxygen concentrator noise ≤ 45dB).

    Long-lasting and durable

    The industrial cartridge supports blowback cleaning and repeated use; the medical cartridge is hydrophobic, moisture-proof and mold-proof.

    Flexible customization

    Size, precision, flow rate can be adjusted according to the needs of the equipment (e.g. customized anti-static cartridge for flammable workshop).

    Oxygen Concentrator Filters Application

    Fields Application Scenarios Filter Element Types
    Healthcare Hospital oxygen concentrator, home oxygen concentrator, respirator Ultra-high polymer polyethylene cartridge (sterile)
    Industrial oxygen production Air separation equipment, steel mills blast furnace air, gas turbines Self-cleaning dust removal cartridge (high temperature)
    Environmental protection equipment Workshop dust removal system, generator set intake filtration Oil and waterproof film cartridge
    Life Scenarios Household oxygen concentrator, car oxygen bar, pet oxygen chamber Small washable cartridge
    Oxygen Concentrator Filters ensure oxygen safety in medical, industrial and household scenarios through precision filtration and structural innovations (e.g. water closure technology, self-cleaning design). Future trends will focus on intelligent life monitoring (e.g. colorful rope clogging tips) and the application of environmentally friendly biodegradable materials to further reduce maintenance costs and environmental load.

    Frequently Asked Questions (FAQ)

    How often should an oxygen concentrator filter be replaced or cleaned?
    For household oxygen concentrators, filters are typically inspected and cleaned regularly or replaced every 3 to 6 months. In industrial settings, the operational lifespan averages approximately 2,200 hours, though harsh or heavily dusted environments may require earlier replacement.
    What is the filtration efficiency of medical-grade oxygen filters?
    Medical-grade oxygen concentrator filters provide high-efficiency HEPA-level filtration with a 0.3-5μm precision rating, achieving an interception rate of ≥ 99.9% for fine airborne particles (PM2.5), bacteria, and microbes.
    How do these filters contribute to noise reduction in oxygen generators?
    The filters incorporate a specialized acoustic pore structure combined with muffler integration that dampens high-velocity airflow noise, maintaining household oxygen concentrator operating sound levels at or below 45dB.
    What materials are used to ensure medical-grade biocompatibility?
    Medical cartridges are manufactured under sterile conditions using medical-grade ultra-high molecular weight polyethylene (UHMWPE), providing excellent biocompatibility, hydrophobic properties, and resistance to moisture and mold.
    Are custom dimensions and specifications available for OEM/ODM requirements?
    Yes, dimensions, airflow capacity, filtration precision, and specific technical features (such as water self-sealing pressure barriers or anti-static treatments) can be tailored to match exact equipment requirements.